Confirm which obligations apply to the proposed site
Give King County Permitting the parcel number, project name and permit number if available. Confirm that the site is in unincorporated King County and that the project is subject to King County Code § 21A.08.100.B.30. That provision excludes systems classified as accessory uses under §§ 21A.06.015, .020 or .025. Ask for the County's determination based on the actual proposal.
For a covered system above 2 MW, the public liability and environmental risk requirement applies if all three conditions hold. The technology requires thermal runaway compliance under WAC 51-54A-1207.6. At least one enclosure is rated above 2 megawatt-hours (MWh) or any two enclosures are closer than 10 feet. The system also falls outside the remote installation classification under International Fire Code § 1207.8.1.
Ask for the capacity, equipment schedule and site plan used in the application. The project capacity threshold uses MW. The individual enclosure energy rating uses MWh. Ask County Permitting and the project professionals to confirm the technology and remote installation classifications from those records.

Match the amounts in the package to both obligations
When the liability and environmental risk requirement applies, § 21A.49.010(B) calls for $1 million in financial responsibility responsive to the applicant's payment of damages to people and property caused by a thermal event. An applicant can voluntarily obtain a higher amount. For decommissioning, § 21A.49.010(D) requires enough to carry out all contingencies in the required plan. The estimate must use current dollars and the cost of hiring a third party for the work. It must exclude any net present value adjustment and any salvage-value credit.
The code allows the applicant to package both obligations together. The decommissioning amount must be additional to any required thermal-event liability amount. If the developer presents one package, ask it to identify the evidence and amount for each obligation. Ask the County what evidence is on file and how it treats each amount. The County's permit records service can help locate the available records. Get complete instruments and current amendments from the developer for private review.
Ask your counsel and insurance adviser to review the actual instruments and the lease for claim rights, exclusions, notice and renewal terms, and any private cleanup, indemnity or restoration commitments. A County filing answers what the developer submitted. The instruments and the agreement supply the terms you need to check for your own deal.
Check the permit date and the next verification
Financial responsibility must be maintained throughout facility operations. For either applicable requirement, the applicant must submit verification to the County every five years, beginning five years after permit issuance. For a renewal or sale at an operating site, ask the County to confirm the issuance date, what verification it has received and the next due date. Check the expiry and renewal dates on each instrument and the deadlines in your agreement separately.
Want to ask about your land?
Send the location and what you know. You don’t need a project plan.
Tell us about your landDiscuss your battery storage property or agreement
Sunland America welcomes inquiries from owners and authorized representatives nationwide about selling or leasing battery storage property or discussing an existing agreement. Share the general location, your role, the permit stage and the decision date. Keep signed agreements, policies and other financial instruments for private follow-up.
Questions landowners ask
When does the developer show financial responsibility to King County?
The applicant shows each applicable obligation as part of submitting the building permit application. Ask the developer for the submission and the County for its permit record or current status.
Can one package meet both requirements?
Yes. The code permits a combined package when the decommissioning amount is additional to any required public liability amount. Ask how the instruments show the amount and scope of each obligation.
When does the County require proof again?
For either applicable obligation, the applicant submits verification every five years, starting five years from permit issuance. Check the County's issuance date and the individual instrument dates before relying on the documents at closing or renewal.
Sources & further reading
King County Code, enacted County ordinances, Washington's energy storage system rule and the County's permit records guidance were checked November 22, 2026. Local rules and program details can change. Check the requirements for the actual project.
- King County Ordinance 20082, § 86, regional land uses and battery storage permit triggers
- King County Ordinance 19824, § 10, building permit application triggers and verification
- King County Ordinance 19824, § 17, financial responsibility amounts and forms
- King County Code, Title 21A, § 21A.49.010, demonstration of financial responsibility
- Washington Administrative Code 51-54A-1207, state energy storage systems requirements
- King County Permitting Records Center, permit records research